Use these line set seals on my (2) mini splits for my garage. The seals fit over the male flare face, they have a thin coating of dried blue Loctite, these are made for HVAC service. For a test I applied about <6lbs torque on both the 1/4" and 3/8" line's male flares, far below either of the lines recommended torque setting. Both fitting were leak proof at 500psi. When I was ready to open the lineset valves valves I warmed the fitting to about 180° F, and torqued the fittings to 12.5ftp (1/4") and 25.5ftp for the 3/8" to bring the torque to the recommended amount, again no leaks at 500 psi, vacuum settled steady at 250 micron.
Mind you I would not have had any leaks without the seals but I used the flaretites as insurance for possible future expansion/contraction and vibration leaks. Cheap insurance, great product.
rectorseal.com
Mind you I would not have had any leaks without the seals but I used the flaretites as insurance for possible future expansion/contraction and vibration leaks. Cheap insurance, great product.
Flaretite
Features 45° Copper Stamping with Loctite coating Locking tabs clip seal securely on fitting Conical rings for multiple points of contact Made for all common 45° fittings Rated for -40°C to 149°C (-40°F to 300°F) Pressure rated up to 689 bar (10,000 psi)